l Brief Introduction
The Disposable trocar is mainly composed of a trocar cannula assembly and a puncture rod assembly. The trocar cannula assembly consists of upper shell, valve body, valve core, choke valve and lower casing. The puncture rod assembly is mainly composed of puncture cap, button, puncture tube and piercing head.
It is sterilized by ethylene oxide. It direct contace with human body for no more than 60minutes.
Intended use
It is suitable for puncturing human abdominal wall tissue during laparoscopic examination and operation, and establishing working passage for abdominal operation.
l Contraindications
This instrument can not be used in general contraindications of endoscopic surgery.
l Attention
1. Endoscopic surgery can only be performed by physicians who have rich experience and are familiar with endoscopic techniques. Before surgery, physicians should consult relevant books and literature to understand the technology, complications and risks of endoscopy.
2. In the process of abdominal surgery, if the appropriate pneumoperitoneum is not formed and maintained, the available operating space may be reduced, thus hindering the forward movement of the puncture rod and increasing the risk of visceral tissue injury.
3. During laparoscopic abdominal surgery, patients should be in the head-down, foot-high supine position. When using the first puncture cannula, lift the lower abdominal wall with one hand and insert the cannula into the bladder at an angle of 45 degrees from the umbilical skin incision with the other hand.
4. Adhesion, anatomical abnormalities or other obstacles may prevent or delay, it may cause damage to internal organ structure of puncture head during blind puncture,Open laparoscopic surgery is recommended. After suturing the peritoneal fascia, introduce the product into the abdominal cavity for use.
5. Once the puncture cannula is in the abdominal cavity, care must be taken not to re-pressurize it. If enough force is applied to the front end to move the cone forward, it will cause damage to the internal organization.
6. After successful puncture, before using endoscopy instruments, apply medical lubricant on the surface of endoscopy instruments or the sealing ring of puncture devices, so as to reduce resistance and make the operation more convenient and fast.
7. When using endoscopic instruments and accessories produced by different manufacturers at the same time in endoscopic surgery, the compatibility between different instruments should be checked, and the electrical insulation and grounding should be checked.
8. Before and after removal of the disposable puncture cannula from the abdominal cavity, please check the hemostasis of the surgical site. Hemorrhage can be controlled by electric burn or manual suture. According to the doctor's judgment, a laparotomy may be necessary.
9. If the skin incision is 10 mm or longer, the deep fascia should be closed to reduce the possibility of incisional hernia.
WZDT-A-10
Microcure
9018909919
Availability: | |
---|---|
Disposable trocar is mainly composed of a trocar cannula assembly and a puncture rod assembly. The trocar cannula assembly consists of upper shell, valve body, valve core, choke valve and lower casing. The puncture rod assembly is mainly composed of puncture cap, button puncture tube and piercing head.
It is sterilized by ethylene oxide. It direct contace with human body for no more than 60minutes.
Scope of application:
Applicable to the establishment of microports for introduction of endoscopes and laparoscopic
instruments.
Product features:
1. Visible puncture design, with transparent puncture rob tip,camera can be placed in puncture to prevent accidental tissue injury.
2. The design of double valves,makes good air tightness and no need for converter during operation.
3. The cannula and sealing caps are separable,which allows the easy removal of tissue during operation
4. The ergonomic grip design makes the comfortable handling of the device
5. The reverse thread design,makes the insertion smooth,and prevents the undesired movement and operation.
6. The fin type design makes insertion smooth
Specifications&Models:
SPECIFICATION | MODELS | PACKAGE CONTENT | CASING WORKING LENGTH (mm) |
Set package1 | VT5-100 | 5mm Trocarx2 | 103 |
VT8-100 | 10mm Trocarx2 | 103 | |
V12-100 | 12mm Trocarx2 | 103 | |
Set package2 | V19-100 | 5mm Trocarx2+10mm Trocarx1 | 103 |
VT25-100 | 5mm Trocarx1+10mm Trocarx2 | 103 | |
VT28-100 | 5mm Trocarxl+12mm Trocarx2 | 103 | |
Set package3 | VT40-100 | 5mm Trocarx2+10mm Trocarx2 | 103 |
VT43-100 | 5mm Trocarx2+12mm Trocarx2 | 103 | |
VT46-100 | 5mm Trocarx2+10mm Trocarx1+12mm Trocarx1 | 103 | |
Set package4 | VT60-100 | 5mm Trocarx2+10mm Trocarx2+12mm Trocarx1 | 103 |
VT61-100 | 5mm Trocarx2+10mm Trocarx1+12mm Trocarx2 | 103 | |
Individual | WZDT-A-3/55 | 3mm Trocarx1 | 55 |
WZDT-A-5/100 | 5mm Trocarx1 | 103 | |
WZDT-A-10/100 | 10mm Trocarx1 | 103 | |
WZDT-A-12/100 | 12mm Trocarx1 | 103 | |
WZDT-A-15/100 | 15mm Trocarx1 | 103 |
Disposable trocar is mainly composed of a trocar cannula assembly and a puncture rod assembly. The trocar cannula assembly consists of upper shell, valve body, valve core, choke valve and lower casing. The puncture rod assembly is mainly composed of puncture cap, button puncture tube and piercing head.
It is sterilized by ethylene oxide. It direct contace with human body for no more than 60minutes.
Scope of application:
Applicable to the establishment of microports for introduction of endoscopes and laparoscopic
instruments.
Product features:
1. Visible puncture design, with transparent puncture rob tip,camera can be placed in puncture to prevent accidental tissue injury.
2. The design of double valves,makes good air tightness and no need for converter during operation.
3. The cannula and sealing caps are separable,which allows the easy removal of tissue during operation
4. The ergonomic grip design makes the comfortable handling of the device
5. The reverse thread design,makes the insertion smooth,and prevents the undesired movement and operation.
6. The fin type design makes insertion smooth
Specifications&Models:
SPECIFICATION | MODELS | PACKAGE CONTENT | CASING WORKING LENGTH (mm) |
Set package1 | VT5-100 | 5mm Trocarx2 | 103 |
VT8-100 | 10mm Trocarx2 | 103 | |
V12-100 | 12mm Trocarx2 | 103 | |
Set package2 | V19-100 | 5mm Trocarx2+10mm Trocarx1 | 103 |
VT25-100 | 5mm Trocarx1+10mm Trocarx2 | 103 | |
VT28-100 | 5mm Trocarxl+12mm Trocarx2 | 103 | |
Set package3 | VT40-100 | 5mm Trocarx2+10mm Trocarx2 | 103 |
VT43-100 | 5mm Trocarx2+12mm Trocarx2 | 103 | |
VT46-100 | 5mm Trocarx2+10mm Trocarx1+12mm Trocarx1 | 103 | |
Set package4 | VT60-100 | 5mm Trocarx2+10mm Trocarx2+12mm Trocarx1 | 103 |
VT61-100 | 5mm Trocarx2+10mm Trocarx1+12mm Trocarx2 | 103 | |
Individual | WZDT-A-3/55 | 3mm Trocarx1 | 55 |
WZDT-A-5/100 | 5mm Trocarx1 | 103 | |
WZDT-A-10/100 | 10mm Trocarx1 | 103 | |
WZDT-A-12/100 | 12mm Trocarx1 | 103 | |
WZDT-A-15/100 | 15mm Trocarx1 | 103 |
content is empty!