Disposable Hemorrhoid Stapler provide two loops of interlaced staples. After the stitching is formed, the internal ring blade of the instrument can remove the excess tissue and form a circular anastomosis.
WZHS-A
Availability: | |
---|---|
Quantity: | |
Disposable Hemorrhoid Stapler provide two loops of interlaced staples. After the stitching is formed, the internal ring blade of the instrument can remove the excess tissue and form a circular anastomosis.
Scope of application:
Applicable for selective resection and suturing of dentate line mucosa.
Product features:
1.The thickness can be adjusted according to the actual condition of prolapse.
2. Minimum suture clearance is provided to avoid excessive pressure injury.
3.Reasonable staple density to reduce postoperative bleeding.
4. The large volume of the staple bin can accommodate more organizations.
5.Four suture hole,wider surgical sight
6.Bigger indicator window
7.Larger cartridge,more capacity warehouse
Specifications&Models:
Models | TOTAL LENGTH(mm) | OUTER DIAMETER(mm) | STAPLER HEIGHT(mm) | STAPLER DIAMETER(mm) |
WZHS-A-32 | 395 | 32 | 3.8 | 0.28 |
WZHS-A-33 | 395 | 33.5 | 3.8 | 0.28 |
WZHS-A-34 | 395 | 34 | 3.8 | 0.28 |
Disposable Hemorrhoid Stapler provide two loops of interlaced staples. After the stitching is formed, the internal ring blade of the instrument can remove the excess tissue and form a circular anastomosis.
Scope of application:
Applicable for selective resection and suturing of dentate line mucosa.
Product features:
1.The thickness can be adjusted according to the actual condition of prolapse.
2. Minimum suture clearance is provided to avoid excessive pressure injury.
3.Reasonable staple density to reduce postoperative bleeding.
4. The large volume of the staple bin can accommodate more organizations.
5.Four suture hole,wider surgical sight
6.Bigger indicator window
7.Larger cartridge,more capacity warehouse
Specifications&Models:
Models | TOTAL LENGTH(mm) | OUTER DIAMETER(mm) | STAPLER HEIGHT(mm) | STAPLER DIAMETER(mm) |
WZHS-A-32 | 395 | 32 | 3.8 | 0.28 |
WZHS-A-33 | 395 | 33.5 | 3.8 | 0.28 |
WZHS-A-34 | 395 | 34 | 3.8 | 0.28 |
Q:What is the difference between the first-generation and second-generation anorectal staplers?
A: second-generation has bigger Window display design, the closing height of the staple cartridge can be adjusted easy according to the thickness of the tissue .Larger tissue accommodation and cutting space
Q:What is the difference between the first-generation and second-generation anorectal staplers?
A: second-generation has bigger Window display design, the closing height of the staple cartridge can be adjusted easy according to the thickness of the tissue .Larger tissue accommodation and cutting space